IO-Link modules

Convert standard digital and analog signals into smart IO-Link data with a single M12 cable.

What is an IO-Link Module?

While an IO-Link Master acts as the gateway, IO-Link Modules (or I/O Hubs) act as collectors. They allow you to connect “dumb” devices—like standard binary sensors, pushbuttons, and lights—into your IO-Link network. This transforms a cluster of traditional wiring into a single, streamlined digital stream.

Enquire Now

Let us help you

Why Choose IO-Link Modules?

Massive Wiring Savings: Replace bulky 16-core cables and expensive terminal boxes with one standard 3-wire M12 cable.

Decentralised Control: Mount modules directly on the machine (IP67) to reduce cable runs back to the control cabinet.

Universal Ports: Many modules feature “Pin 2/Pin 4” configurability, allowing you to use one port for two digital inputs or as a diagnostic channel.

Analog-to-Digital Conversion: Convert 4-20mA or 0-10V analog signals into IO-Link data right at the source, eliminating EMI/RFI interference over long distances.

Top Performance Modules

Product TypeTop RecommendationKey Feature
Digital I/O HubBalluff BNI IOL-30216 Configurable Inputs/Outputs in a rugged metal housing.
Analog Converterifm DP2200Converts any 4-20mA analog sensor into a smart IO-Link device.
Valve PlugMurrelektronik Impact67Direct connection for solenoid valves to the IO-Link Master.

Technical Comparison

FeatureDigital HubsAnalog Converters
Input TypePNP / NPN / Binary4-20mA / 0-10V / RTD
Port StyleM12 or M8M12 (Single or Dual)
ProtectionIP67 (Washdown)IP65 / IP67 / IP69K
DiagnosticsShort circuit & OverloadSignal out-of-range & Wire break

Application Spotlight: The "One Cable" Machine

By using an IO-Link Master in the cabinet and IO-Link I/O Modules on the machine frame, you can reduce installation time by up to 40%.
  1. The Master connects to the PLC (PROFINET/EtherNet).
  2. The Hubs collect data from dozens of simple limit switches and pilot lights.
  3. The Result: A clean, “tangle-free” machine with full remote visibility into every single sensor.

IFM IO-Link modules

Input modules for IO-Link devices

Up to eight conventional sensors with switching outputs can be connected to the field modules with IO-Link. The signals are transmitted to any desired IO-Link master / PLC via one unscreened M12 connection cable. This considerably reduces wiring complexity since conventional parallel wiring of each sensor or actuator to the controller is no longer necessary. It also saves the user a great number of terminals, splitter boxes, input/output cards and cable lines. As opposed to bus systems IO-Link does not require any configuration or addressing. This simplifies the set-up. Excellent electromagnetic stability, a wide temperature range, a high protection rating and a robust housing qualify the device for use in harsh industrial environments.

Enquire Now

Fill up the form and we will get back to you in 24 hours