Render Automation Pvt. Ltd. deal with all kinds of IFM Flow Sensor
In almost all industrial processing plants, liquids or gases are used in operations. ifm product range of flow sensors offer different measuring principles, materials, and displays to meet the requirements of many different needs across industries. Commonly, manufacturing facilities rely on flow sensors to monitor varied types of media, from water, oils, and coolants, to gases, compressed air, and aggressive media. Electronic flow sensors can prevent damage or downtime caused by flow interruptions, and have a longer lifecycle than traditional mechanical parts that have critical failure points. Their application areas range from simple monitoring tasks to precise flow rate measurements. Use the Select By Application tool to narrow your search for a flow sensor based on media type, and read more about the underlying measuring principles and technology. Find water flow switches, flow meters for oils, gas flow meters, and deionized water flow sensors from the various ifm platforms.
Sensor Family | Flow Rate | Line Size | Medium Temperature | Accuracy | Points to Consider |
---|---|---|---|---|---|
![]() SB |
0.1…50 gpm | 3/4"…1-1/2" | 14…212 °F -10…100 °C |
~ ±5% | • No straight pipe runs required • Response time ≤ 10 msec • Pressure ≤ 580 psi • Oil viscosity ≤ 46 cSt |
![]() SU |
0…52.8 gpm | 1/2"…1" | 14…176 °F -10…80 °C |
~ ±5% | • Totalizer function • Pressure ≤ 232 psi • Oil viscosity ≤ 68 cSt |
![]() SA |
0.1…5400 gpm | 1/2"…16" | -4…212 °F -20…100 °C Higher upon request |
~ ±10% | • Pressure ≤ 1450 psi • Avoid rapid medium temperature changes |
![]() SI |
3…100 cm/s | 1/8"…8" | -13…176 °F -25…80 °C |
~ ±10% | • Pressure < 4350 psi • Sanitary versions available • Avoid rapid medium temperature changes |
Sensor Family | Flow Rate | Line Size | Medium Temperature | Accuracy | Points to Consider |
---|---|---|---|---|---|
![]() SD |
0…412 scfm | 1/2"…2" | 32…140 °F 0…60 °C |
~ ±3% | • Totalizer function • Pressure ≤ 232 psi • Monitor air, CO2, N2 and Ar |
![]() SA |
1…27000 scfm | 1/2"…16" | -4…212 °F -20…100 °C Higher upon request |
~ ±15% | • Pressure ≤ 1450 psi • Avoid rapid medium temperature changes |
![]() SI |
3…100 cm/s | 1/8"…8" | -13…176 °F -25…80 °C |
~ ±10% | • Pressure < 4350 psi • Sanitary versions available • Avoid rapid medium temperature changes |
Sensor Family | Flow Rate | Line Size | Medium Temperature | Accuracy | Points to Consider |
---|---|---|---|---|---|
![]() SV |
0.26…26.4 gpm | 1/2"…3/4" | 14…194 °F -10…90 °C |
~ ±2% | • Display flow and temperature • Water content ≥ 95% • Pressure rating ≤ 174 psi • Long straight pipe required |
![]() SU |
0…52.8 gpm | 1/2"…1" | 14…176 °F -10…80 °C |
~ ±5% | • Totalizer function • Pressure ≤ 232 psi |
![]() SA |
0.1…5400 gpm | 1/2"…16" | -4…212 °F -20…100 °C Higher upon request |
~ ±10% | • Pressure ≤ 1450 psi • Avoid rapid medium temperature changes |
![]() SI |
3…100 cm/s | 1/8"…8" | -13…176 °F -25…80 °C |
~ ±2% | • Pressure < 4350 psi • Sanitary versions available • Avoid rapid medium temperature changes |